Linearized measured value display from -20.0...+60.0℃
Platinum-resistance element PT 100 for a maximum of stability Special form of the sensor element results in low response times Data processing by microcontroller system
Output range of the output signal is variable Illuminated four-digit display
Adjustments or status enquiries by means of a press button unit or a magnetic pointer. The housing need not be opened
Code lock to prevent unauthorized manipulation (can be switched off)
Fault self diagnosis with alpha numeric display
Test of the output signal by simulated values Choice between normed analog or digital output signals (optional)
Two built-in limit switches with optocouplers or relays in the monitor Audio visual alarm unit optional (Monitor)
Sensor can be replaced on site Housing protection rating IP65